{"id":15018,"date":"2024-09-25T10:40:28","date_gmt":"2024-09-25T07:40:28","guid":{"rendered":"https:\/\/www.sahinrulman.com\/hybrid-servo-drive-ss1108\/"},"modified":"2024-09-25T10:40:28","modified_gmt":"2024-09-25T07:40:28","slug":"hybrid-servo-drive-ss1108","status":"publish","type":"product","link":"https:\/\/www.sahinrulman.com\/en\/hybrid-servo-drive-ss1108\/","title":{"rendered":"Hybrid Servo Drive SS1108"},"content":{"rendered":"<h2 style=\"text-align: center;\"><a href=\"https:\/\/www.sahinrulman.com\/hibrit-servo-surucu-SS1108\">Hybrid Servo Drive SS1108<\/a><b><\/b><\/h2>\n<p><b>Hybrid Servo Drive Voltage:<\/b> 70VAC~130VAC<\/p>\n<p><b>Hybrid Servo Drive Current:<\/b> 8.0AMPS<\/p>\n<p><b>Hybrid Servo Drive:<\/b> 2 Phase Servo Drive<\/p>\n<p><b>Product Code: <\/b><b><a href=\"https:\/\/www.sahinrulman.com\/site\/images\/stories\/teknik-ozellikler\/enkoderli-step-motor-surucu\/hibrit-servo-surucu-SS1108_E.pdf\" target=\"_blank\" rel=\"noopener\">Hybrid Servo Drive SS1108<\/a><\/b><\/p>\n<p><b>Motor Mounting<\/b><\/p>\n<p>BLUE: A+<\/p>\n<p>YELLOW: A-<\/p>\n<p>BLACK: B+<\/p>\n<p>RED: B-<\/p>\n<p><b>2 Phase Encoder Stepper Motor Driver SS1108<\/b><\/p>\n<p>The metal part of the panel where the drives are located must be EARTHED. Before giving Amperes to the drives, a voltage control must be done by entering a measuring device between NEUTRAL and EARTH cables.  The ideal situation is zero volts.<\/p>\n<p>In PLC, Arduino, Axis control card or specially designed cards, PULSE and DIR signals must be sent as 5V. For devices with signal outputs above 5 Volts, resistance must be entered into the PULSE and DIR signal output cables to be distributed individually in minus or plus driving. For example, the resistance required for 24Volt output is 1.8K\u03a9. <\/p>\n<p> <b>ALARM USE;<\/b> ALARM connection of the drive is normally open dry contact. The use of ALARM required for CNC routers, ALM + outputs of hybrid servo drives on all axes for parallel connection are bridged between themselves and ALM &#8211; outputs are bridged between themselves. If the axis control card signal input is negative, the ALM &#8211; lead is connected to the power supply &#8211; output, the ALM + lead is connected to the E-Stop input. When any of the drives on the axes are alarmed, the signal will reach E-stop and mach3 will make emergency stop. It is ensured that the signal from the power supply is 5Volt or 24 Volt as acceptable by the axis control card.<br \/>\nSince the inputs are + in PLCs, ALM +s will all be connected to the PLC FEED 24 Volt +, ALM -s will be combined and connected to the input input selected for the alarm.    <\/p>\n<p><b>PEND USE: <\/b>The PEND connection of the drive is a normally closed dry contact. By connecting in series, PEND + of the first driver is connected to the power supply, PEND &#8211; is connected to the PEND + input of the other driver. PEND &#8211; output of the last driver is connected to the input input. Since it is normally closed, there is a continuous signal. The signal is cut off when an alarm occurs.    <\/p>\n<p>&nbsp;<\/p>\n<p><b>Please click here for product video (1) :<\/b> <b><a href=\"https:\/\/www.youtube.com\/watch?v=p7aqe4TsOZc\" target=\"_blank\" rel=\"noopener\">Hybrid Servo Drive<\/a><\/b><\/p>\n<p><b>Please click here for product video (2) :<\/b> <b><a href=\"https:\/\/youtu.be\/O4eHEtMJaBs\" target=\"_blank\" rel=\"noopener\">Hybrid Servo Drive<\/a><\/b><\/p>\n<p><b>Please click here for product video (3) :<\/b> <b><a href=\"https:\/\/youtu.be\/41IPKNIW2eA\" target=\"_blank\" rel=\"noopener\">Hybrid Servo Drive<\/a><\/b><\/p>\n<h4><b>Hybrid Servo Drive SS1108 Product Video<\/b><\/h4>\n<p>&nbsp;<\/p>\n<p><iframe class=\"note-video-clip\" style=\"color: inherit; font-family: inherit;\" src=\"\/\/www.youtube.com\/embed\/cG7i77y3y8U?rel=0\" width=\"100%\" height=\"360\" frameborder=\"0\"><\/iframe><\/p>\n<p>&nbsp;<\/p>\n<p style=\"margin-top: 10px; margin-bottom: 15px; padding: 0px;\">The maximum power parameter settings allowed by the factory for SS1108 drives are as follows.<\/p>\n<p style=\"margin-top: 10px; margin-bottom: 15px; padding: 0px;\">86BHH76-380p-40Mp =&gt; PR001-&gt;25, PR004-&gt;50<\/p>\n<p style=\"margin-top: 10px; margin-bottom: 15px; padding: 0px;\">86BHH114-450p-40Mp =&gt; PR001-&gt;45, PR004-&gt;70<\/p>\n<p style=\"margin-top: 10px; margin-bottom: 15px; padding: 0px;\">86BHH150-600-40Mp =&gt; PR001-&gt;40, PR004-&gt;70<\/p>\n<p style=\"text-align: center; margin-top: 10px; margin-bottom: 15px; padding: 0px;\"><b><span style=\"color: #ff0000;\"><u> <\/u><\/span><\/b><\/p>\n<p style=\"text-align: center; margin-top: 10px; margin-bottom: 15px; padding: 0px;\"><b><span style=\"color: #ff0000;\"><u> <\/u><\/span><\/b><\/p>\n<p style=\"text-align: center; margin-top: 10px; margin-bottom: 15px; padding: 0px;\"><b><span style=\"color: #ff0000;\"><u>ALARM CONDITIONS<\/u><\/span><\/b><\/p>\n<table border=\"0\" frame=\"VOID\" rules=\"NONE\" cellspacing=\"0\">\n<colgroup>\n<col width=\"165\">\n<col width=\"446\">\n<col width=\"649\"><\/colgroup>\n<tbody>\n<tr>\n<td style=\"border: 1px solid #000000;\" align=\"CENTER\" width=\"165\" height=\"17\"><b><span style=\"color: #ff6600;\">PROBLEMS<br \/>\n<\/span><\/b><\/td>\n<td style=\"border: 1px solid #000000;\" align=\"CENTER\" width=\"446\"><b><span style=\"color: #ff6600;\">POSSIBLE CAUSES<br \/>\n<\/span><\/b><\/td>\n<td style=\"border: 1px solid #000000;\" align=\"CENTER\" width=\"649\"><b><span style=\"color: #ff6600;\">SOLUTIONS<\/span><\/b><\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000000;\" rowspan=\"4\" align=\"LEFT\" valign=\"MIDDLE\" height=\"69\"><b><span style=\"color: #ff6600;\">Motor Does Not Rotate<\/span><\/b><\/td>\n<td style=\"border: 1px solid #000000;\" align=\"LEFT\"><b>No electricity<\/b><\/td>\n<td style=\"border: 1px solid #000000;\" align=\"LEFT\"><b> Check the electrical input<\/b><\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000000;\" rowspan=\"2\" align=\"LEFT\" valign=\"MIDDLE\"><b>Pulse signal does not reach the driver<\/b><\/td>\n<td style=\"border: 1px solid #000000;\" align=\"LEFT\"><b>Check signal input<\/b><\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000000;\" align=\"LEFT\"><b>The signal is given as 24 Volts, a 1.8k\u03a9 resistor will be connected to the PULSE and DIR inputs, or the pulse signal comes at too low voltage. It can be understood by measuring the voltage of the DIR signal. <\/b><\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000000;\" align=\"LEFT\"><b> Drive is DISABLED<\/b><\/td>\n<td style=\"border: 1px solid #000000;\" align=\"LEFT\"><b>ENABLE inputs are receiving a 5 volt signal, turn off the signal<\/b><\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000000;\" align=\"LEFT\" height=\"17\"><b><span style=\"color: #ff6600;\">ALM Err_00<\/span><\/b><\/td>\n<td style=\"border: 1px solid #000000;\" align=\"LEFT\"><b>High Voltage<\/b><\/td>\n<td style=\"border: 1px solid #000000;\" align=\"LEFT\"><b>Check the power supply output voltage (drive supply voltage)<\/b><\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000000;\" align=\"LEFT\" height=\"17\"><b><span style=\"color: #ff6600;\">ALM Err_01<\/span><\/b><\/td>\n<td style=\"border: 1px solid #000000;\" align=\"LEFT\"><b>High Voltage<\/b><\/td>\n<td style=\"border: 1px solid #000000;\" align=\"LEFT\"><b>Check the power supply output voltage (drive supply voltage)<\/b><\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000000;\" align=\"LEFT\" height=\"17\"><b><span style=\"color: #ff6600;\">ALM Err_02<\/span><\/b><\/td>\n<td style=\"border: 1px solid #000000;\" align=\"LEFT\"><b>High Amps<\/b><\/td>\n<td style=\"border: 1px solid #000000;\" align=\"LEFT\"><b>Check the motor cables and correct the short circuit. The drive trips as soon as it is switched on <\/b><\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000000;\" rowspan=\"4\" align=\"LEFT\" valign=\"MIDDLE\" height=\"69\"><b><span style=\"color: #ff6600;\">ALM Err_03<\/span><\/b><\/td>\n<td style=\"border: 1px solid #000000;\" align=\"LEFT\"><b>Incorrectly connected encoder cable<\/b><\/td>\n<td style=\"border: 1px solid #000000;\" align=\"LEFT\"><b>As soon as the movement starts, the display counter advances a little bit to alarm because there is no encoder signal. Check the encoder connection. Check that the sockets are fully seated. Check if there is a broken wire in the encoder cable. The motor encoder output cable may be broken by force or the encoder reader board behind the motor may be broken. The encoder disk may have slipped out of place or scorched due to high temperature. Replace the encoder cable, replace the encoder reader, replace the encoder disk, set parameter 14=&gt;1 and turn the drive to open loop mode, i.e. turn off encoder tracking.      <\/b><\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000000;\" align=\"LEFT\"><b>Motor cable incorrectly connected<\/b><\/td>\n<td style=\"border: 1px solid #000000;\" align=\"LEFT\"><b>Check the motor cable. The motor cable color sequence is important (blue, yellow, black, red). The drive trips as soon as it is switched on. The extension cable between the drive and the motor may be broken or split at the junction.   <\/b><\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000000;\" align=\"LEFT\"><b>Step missed it.<\/b><\/td>\n<td style=\"border: 1px solid #000000;\" align=\"LEFT\"><b>Turn the drive off and on. <\/b><b>The motor shaft may be contracted. There may be mechanical jamming.  <\/b><b style=\"background-color: transparent;\">Test by taking the engine out and running it at idle. Remove any mechanical binding. Replace with a larger motor.  <\/b><b><br \/>\n<\/b><\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000000;\" align=\"LEFT\"><b>Motor or drive is defective<br \/>\n<\/b><\/td>\n<td style=\"border: 1px solid #000000;\" align=\"LEFT\"><b>Replace motor or drive<\/b><\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000000;\" rowspan=\"2\" align=\"LEFT\" valign=\"MIDDLE\" height=\"34\"><b><span style=\"color: #ff6600;\">Don&#8217;t go to the wrong position<\/span><\/b><\/td>\n<td style=\"border: 1px solid #000000;\" align=\"LEFT\"><b>Microstep setting is incorrect<\/b><\/td>\n<td style=\"border: 1px solid #000000;\" align=\"LEFT\"><b>Set parameter 8 to the correct coefficient (factory value 1600 pulse=1 turn)<\/b><\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000000;\" align=\"LEFT\"><b>Control signal is receiving interference<br \/>\n<\/b><\/td>\n<td style=\"border: 1px solid #000000;\" align=\"LEFT\"><b>Remove the parasite by grounding<\/b><\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000000;\" rowspan=\"2\" align=\"LEFT\" valign=\"MIDDLE\" height=\"34\"><b><span style=\"color: #ff6600;\">Stopping the engine in motion<\/span><\/b><\/td>\n<td style=\"border: 1px solid #000000;\" align=\"LEFT\"><b>Power supply output voltage is too low<\/b><\/td>\n<td style=\"border: 1px solid #000000;\" align=\"LEFT\"><b>Increase drive supply voltage<\/b><\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000000;\" align=\"LEFT\"><b>Departure time is too short<br \/>\n<\/b><\/td>\n<td style=\"border: 1px solid #000000;\" align=\"LEFT\"><b>Extend departure time<\/b><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"margin-top: 10px; margin-bottom: 15px; font-size: 13px; padding: 0px; color: #646464; font-family: Arial, Helvetica, sans-serif;\"><strong><span style=\"font-size: small;\"><strong> <\/strong><\/span><\/strong><\/p>\n","protected":false},"excerpt":{"rendered":"<table class=\"table table-bordered\">\n<thead>\n<tr>\n<td colspan=\"2\"><strong>ENCODER STEPPER MOTOR DRIVER TECHNICAL SPECIFICATIONS<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Voltage<\/td>\n<td>70VAC~130VAC<\/td>\n<\/tr>\n<tr>\n<td>Current\n<\/td>\n<td>8.0 Amps<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":13683,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[570,734,586],"product_tag":[],"class_list":{"0":"post-15018","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-hybrid-servo-drive","7":"product_cat-mechanical-products","8":"product_cat-stepper-motor-driver-with-encoder","9":"tm-no-options","11":"first","12":"instock","13":"taxable","14":"shipping-taxable","15":"purchasable","16":"product-type-simple"},"acf":{"motor_tork_max":"","motor_hiz_max":"","motor_guc":"","motor_calisma_tipi":"surekli","motor_reduktor_durumu":"dahili","step_holding_torque":"","step_nema_size":false,"step_current":"","step_hiz_max":"","step_flange_size":"","ozelligi_ne":[],"uyumlu_surucu":null},"_links":{"self":[{"href":"https:\/\/www.sahinrulman.com\/en\/wp-json\/wp\/v2\/product\/15018","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.sahinrulman.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.sahinrulman.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.sahinrulman.com\/en\/wp-json\/wp\/v2\/comments?post=15018"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.sahinrulman.com\/en\/wp-json\/wp\/v2\/media\/13683"}],"wp:attachment":[{"href":"https:\/\/www.sahinrulman.com\/en\/wp-json\/wp\/v2\/media?parent=15018"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.sahinrulman.com\/en\/wp-json\/wp\/v2\/product_brand?post=15018"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.sahinrulman.com\/en\/wp-json\/wp\/v2\/product_cat?post=15018"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.sahinrulman.com\/en\/wp-json\/wp\/v2\/product_tag?post=15018"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}